Bently Nevada 3300/12 is the AC power module of the 3300 monitoring system, which is designed to provide stable power support for industrial rotating machinery protection systems.

Bently Nevada 3300/12 Key parameters

Parameter

Specification

Conditions

Input Voltage

95–125 VAC or 190–250 VAC

50/60 Hz, field-configurable via jumper

Output Voltage

-24 VDC or -18 VDC

Selectable via jumper (default: -24 VDC)

Max Output Current

5.5 A

At input voltage 20–34 VDC

Fuse Ratings

250V, 1.5 A (95–125 VAC)250V, 0.75 A (190–250 VAC)

Over/Undervoltage protection

Power Capacity

Supports up to 12 monitoring modules

Fully populated rack (e.g., 3300/05-12 slot rack)

Isolation Voltage

1500 Vrms

Input-to-output isolation

Certifications

CSA/NRTL/C, ATEX self-certified

Compatible with industrial hazardous areas

Beneficiary's Bank: CITIBANK N.A.
Beneficiary address:Champion Tower,Three Garden Road,Central,Hong Kong
Beneficiary: Vogi International Trading Co., Limited
Account No.: 395714900
Bank Code: 006 Branch Code: 391
Swift Code:CITIHKHX (CITIHKHXXXX * If 11 characters are required)
Payment Term:T/T

Comparison with similar models and alternatives

Model

Advantages

Disadvantages

Bently Nevada 3300/12

Flexible AC input; Supports fully populated 12-module racks

Limited to 3300 systems; Incompatible with 3500 racks

3300/14 (DC Power Supply)

24 VDC input; Suitable for AC-free environments

Lower output current limit (≤4 A)

Alternative: 3500/92

Supports all 3500 series modules; Integrated System 1® diagnostics

Requires rack and module replacement; Upgrade cost increases by 50%

Alternative: 3701 ADAPT

Distributed architecture; No centralized power rack required

Only supports vib/tach monitoring; Incompatible with temp/DE modules

Upgrade suggestion:

The 3300 series has been discontinued (phased out in 2014), Bently Nevada 3300/12 users can migrate to the 3500/92:

Advantages: Compatible with the original sensor, channel density increased by 40%, and supports real-time power health diagnosis;

Disadvantages: Requires modification of panel opening dimensions (3500 rack height increases by 0.78 inches).

3300-12 3