Bently Nevada 330104-00-04-10-02-00 is a four-channel vibration monitor within the System 1™ platform, designed specifically for protecting critical rotating machinery.

Bently Nevada 330104-00-04-10-02-00 Key parameters

Parameter

Specification

Input Type

Eddy Current Probe / Velocity Seismic

Channels

4 isolated dynamic inputs

Frequency Response

0.5Hz-12kHz (±3dB)

A/D Resolution

24-bit Σ-Δ conversion

Dynamic Range

120 dB (typical)

Alarm Relays

4 programmable SPDT (5A @ 250V AC)

Communication

Modbus TCP/IP via 100BASE-TX

Power Supply

20-60V DC (redundant inputs)

Operating Temperature

-40°C to +85°C

Certification

SIL 2 (IEC 61508), ATEX Zone 2

MTBF

>250,000 hours (per MIL-HDBK-217F)

Beneficiary's Bank: CITIBANK N.A.
Beneficiary address:Champion Tower,Three Garden Road,Central,Hong Kong
Beneficiary: Vogi International Trading Co., Limited
Account No.: 395714900
Bank Code: 006 Branch Code: 391
Swift Code:CITIHKHX (CITIHKHXXXX * If 11 characters are required)
Payment Term:T/T

Bently Nevada 330104-00-04-10-02-00 Key Features

Self-diagnostic redundant architecture

The Bently Nevada 330104-00-04-10-02-00 utilizes a two-out-of-three logic voting mechanism, ensuring safe operation even when a single channel fails in the steam turbine at Saudi Aramco's Ras Tanura refinery. Its onboard BIT (Built-In Test) system performs hardware self-tests every five seconds, increasing the response speed eightfold compared to traditional DCS monitoring.

Radio Frequency Interference (RFI)-Resistant Design

The module's electromagnetic shielding has passed 10V/m RF field strength testing (EN 61000-4-3), reducing the false alarm rate to 0.1% in a high-voltage inverter room at a Canadian oil sands mine. The Bently Nevada 330104-00-04-10-02-00's isolated power supply design successfully blocked lightning-induced currents at a Brazilian hydroelectric power station.

Bently Nevada 330104-00-04-10-02-00 Supporting products

UAE LNG Compressor Unit

Abu Dhabi ADNOC's plant deployed Bently Nevada 330104-00-04-10-02-00 modules on 18 centrifugal compressors. Their -40°C low-temperature start-up capability ensures nighttime operations in the desert. Direct Modbus TCP connectivity to the DCS system reduces surge warning time to 23 seconds, avoiding over $12 million in unplanned downtime annually.

US Nuclear Power Plant Main Pump Monitoring

The Palo Verde Nuclear Power Plant in Arizona uses Bently Nevada 330104-00-04-10-02-00 modules to monitor reactor coolant pumps, achieving 10CFR50 Appendix B nuclear certification. The triple-redundant architecture successfully prevented excessive axial displacement (2.3 mm) during a 2019 earthquake, triggering a safe shutdown.