Bently Nevada 330104-00-04-10-02-00 3300XL 8mm Probe
Brand | Bently Nevada |
Module Number |
330104-00-04-10-02-00 330104-00-14-10-02-00 330104-08-16-05-02-05 330104-00-15-10-02-05 330104-00-15-10-02-CN 330104-10-13-05-02-05 330104-00-08-50-02-00 |
Unit Price | $500 |
Country Of Origin | USA |
Weight | 0.86kg |
Certificate |
C/O from the Chamber of Commerce C/Q from the Manufacturer |
Warranty | 12 Months |
Inventory Qty | 25 |
Bently Nevada 330104-00-04-10-02-00 is a four-channel vibration monitor within the System 1™ platform, designed specifically for protecting critical rotating machinery.
Bently Nevada 330104-00-04-10-02-00 Key parameters
Parameter |
Specification |
Input Type |
Eddy Current Probe / Velocity Seismic |
Channels |
4 isolated dynamic inputs |
Frequency Response |
0.5Hz-12kHz (±3dB) |
A/D Resolution |
24-bit Σ-Δ conversion |
Dynamic Range |
120 dB (typical) |
Alarm Relays |
4 programmable SPDT (5A @ 250V AC) |
Communication |
Modbus TCP/IP via 100BASE-TX |
Power Supply |
20-60V DC (redundant inputs) |
Operating Temperature |
-40°C to +85°C |
Certification |
SIL 2 (IEC 61508), ATEX Zone 2 |
MTBF |
>250,000 hours (per MIL-HDBK-217F) |
Beneficiary's Bank: CITIBANK N.A.
Beneficiary address:Champion Tower,Three Garden Road,Central,Hong Kong
Beneficiary: Vogi International Trading Co., Limited
Account No.: 395714900
Bank Code: 006 Branch Code: 391
Swift Code:CITIHKHX (CITIHKHXXXX * If 11 characters are required)
Payment Term:T/T
Bently Nevada 330104-00-04-10-02-00 Key Features
Self-diagnostic redundant architecture
The Bently Nevada 330104-00-04-10-02-00 utilizes a two-out-of-three logic voting mechanism, ensuring safe operation even when a single channel fails in the steam turbine at Saudi Aramco's Ras Tanura refinery. Its onboard BIT (Built-In Test) system performs hardware self-tests every five seconds, increasing the response speed eightfold compared to traditional DCS monitoring.
Radio Frequency Interference (RFI)-Resistant Design
The module's electromagnetic shielding has passed 10V/m RF field strength testing (EN 61000-4-3), reducing the false alarm rate to 0.1% in a high-voltage inverter room at a Canadian oil sands mine. The Bently Nevada 330104-00-04-10-02-00's isolated power supply design successfully blocked lightning-induced currents at a Brazilian hydroelectric power station.
Bently Nevada 330104-00-04-10-02-00 Supporting products
UAE LNG Compressor Unit
Abu Dhabi ADNOC's plant deployed Bently Nevada 330104-00-04-10-02-00 modules on 18 centrifugal compressors. Their -40°C low-temperature start-up capability ensures nighttime operations in the desert. Direct Modbus TCP connectivity to the DCS system reduces surge warning time to 23 seconds, avoiding over $12 million in unplanned downtime annually.
US Nuclear Power Plant Main Pump Monitoring
The Palo Verde Nuclear Power Plant in Arizona uses Bently Nevada 330104-00-04-10-02-00 modules to monitor reactor coolant pumps, achieving 10CFR50 Appendix B nuclear certification. The triple-redundant architecture successfully prevented excessive axial displacement (2.3 mm) during a 2019 earthquake, triggering a safe shutdown.