Comparison of Woodward 9907-162 and Woodward 9907-164
Category | Woodward 9907-162 | Woodward 9907-164 |
Core Design | Microprocessor-based controller for steam turbines. | Microprocessor-based controller with enhanced real-time processing capabilities. |
Shared Features | - 24 Vdc input, split-stage actuators- NEMA 4X/IP56 enclosure option- RS-232/422/485 interfaces | - Same electrical specs and rugged enclosures- Basic communication protocols included. |
Functionality | Focus: Single extraction/admission control.- Emergency stop, overspeed test buttons.- 8 relay outputs. | Focus: Advanced process automation.- Critical speed avoidance, auto-start sequences.- Modbus and PID integration. |
I/O Configuration | 2 actuator channels, 6 programmable current outputs (4–20 mA). | 16 contact inputs (4 fixed + 12 programmable), 6 configurable analog inputs (4–20 mA). |
Operational Use | Ideal for single-valve turbines in pumps, compressors, or basic industrial systems. | Suited for multi-stage turbines requiring precision (e.g., power plants, grid sync). |
Software | Compatible with OpView™ and 505View for diagnostics. | Supports direct HMI/SCADA integration via Modbus. |
Environmental | Operates at -20°C to +60°C; standard humidity resistance. | Tested for 95% RH at 20–55°C; enhanced moisture resistance. |