IOC16T 200-565-000-013 200-565-000-012 Input/Output Card

Module Number IOC16T
Order Number 200-565-000-013
200-565-000-012
Unit Price $1500
Country Of Origin Switzerland
Weight 0.8kg
Certificate C/O from the Chamber of Commerce
C/Q from the Manufacturer
Warranty 12 Months
Inventory Qty 4

The IOC16T is the core interface unit of the VM600 Condition Monitoring System (CMS), and is designed for real-time vibration and dynamic signal acquisition of rotating machinery.

IOC16T Key parameters

Category

Specification

Physical Profile

Dimensions: 16×16×12 cm (W×H×D); Weight: 0.8 kg

Signal Inputs

16 dynamic channels (BNC connectors): IEPE/ICP accelerometers, proximity probes

Transducer Power

+24 VDC (±1%) constant current, 4 mA per channel

Analog Outputs

4 channels: 0-10 V or 4-20 mA (jumper-selectable), ±0.25% accuracy

Digital Conversion

16-bit DAC for output signals; SNR ≥90 dB

Relay Controls

4 SPDT relays (5 A @ 250 VAC), software-assignable to alarms

Backplane Interface

Industry Pack (IP) via P2 connector to CMC16

EMC Protection

IEC 61000-4-4/4-5 compliant; surge suppression up to 1 kV

Operating Environment

Temp: -30°C to +65°C; Humidity: ≤95% non-condensing

Beneficiary's Bank: CITIBANK N.A. Beneficiary address:Champion Tower,Three Garden Road,Central,Hong Kong Beneficiary: Vogi International Trading Co., Limited Account No.: 395714900 Bank Code: 006 Branch Code: 391 Swift Code:CITIHKHX (CITIHKHXXXX * If 11 characters are required) Payment Term:T/T

IOC16T 2

IOC16T Application Cases

North American combined cycle power plant

GE 7HA.03 gas turbine group uses 32 sets of IOC16T+CMC16 to monitor bearing vibration. The data is output to Emerson Ovation DCS via 4-20mA to achieve automatic load reduction when vibration exceeds the standard.

Northern European offshore wind farm

Equinor Hywind Tampen project deploys 48-channel 013 modules in the variable pitch system, which can withstand low temperature of -25°C and salt spray environment, and the 10-year failure rate is less than 1.2%.

ASEAN LNG plant

Shell FLNG Prelude floating platform integrates 013 modules into the compressor surge control system, triggers the bypass valve through the relay, and avoids unplanned downtime losses of $2.8M/year.