ABB AI820 3BSE008544R1 Analog Input Module
| Brand | ABB |
| Model Number | AI820 |
| Order Number | 3BSE008544R1 |
| Unit Price | $700 |
| Country Of Origin | Sweden and Switzerland |
| Weight | 0.35KG |
| Certificate |
C/O from the Chamber of Commerce C/Q from the manufacturer |
| Warranty | 12 Months |
| Inventory Qty | 5 |
ABB AI820 3BSE008544R1 is a Analog Input Module, it has 4 differential, bipolar
current/voltage inputs.
ABB AI820 Key parameters
|
Parameter |
Specification |
|
Article number |
3BSE008544R1 |
|
Signal specification |
-20..+20 mA, 0(4)..20 mA, -10..+10 V, 0(2)..10 V |
|
Number of channels |
4 |
|
Signal type |
Bipolar differential |
|
Mechanics |
S800 |
Account Number 88800006406771
Account name Vogi International Trading Co., Limited
(* If the account name exceeds the available space, please continue in the address field.)
SWITF/BIC Code WIHBHKHHXXX
Bank name OCBC Hong Kong Branch
Bank address 161 Queen's Road Central, Central, Hong Kong
Country/Region Hong Kong (China)
Account type Business Account
Bank code 035
Payment method For the payment of goods, please make a FPS/CHATS/SWIFT Payment
Notes Please include the following memo/message to receiver when making a payment: [Buyer Name] [Invoice/Contract Number] [Product]
ABB AI820 Features and benefits
4 channels for -20...+20 mA, 0...20 mA, 4...20 mA, -10...+10 V, 0...10 V, 2...10 V, -5...+5 V, 0...5 V, 1...5 V d.c. bipolar differential inputs
One group of 4 channels isolated from ground
14 Bit resolution plus sign
Input shunt resistors protected to 30 V d.c.
The input withstand HART communication
Applications
Process Manufacturing: Used in the chemical, metallurgical, and pharmaceutical industries to monitor process parameters such as reactor temperature, pressure, and flow.
Power and Energy: Used in power systems to monitor various electrical parameters of the power grid and ensure stable system operation.
Utility Infrastructure: Used for automated control and monitoring of water treatment and wastewater treatment plants, as well as heating, ventilation, and air conditioning (HVAC) systems in buildings.

Precautions for Use
Correct Configuration and Wiring: Before use, the input type and range of each channel must be correctly configured via the software. When wiring, always refer to the manual, use the recommended module terminal unit (MTU), and ensure correct polarity to avoid damage to the module.
Environment and Installation: Ensure the operating temperature is within the rated range (e.g., -20°C to +60°C). During installation, ensure signal cables are shielded and grounded, and route them as far away from power cables as possible to minimize interference.
Diagnostics and Maintenance: Modules typically feature status indicators (such as LEDs). Familiarizing yourself with the meaning of these indicators allows for quick diagnosis of communication, power, or channel faults. Hot-swappable functionality allows for replacement of faulty modules without downtime.