Bently Nevada 128240-01 is a three-channel speed/zero speed monitoring module for the 3500 frame, specifically designed for overspeed protection and underspeed interlocking of rotating equipment.
Bently Nevada 128240-01 Key parameters
Parameter |
Specification |
Input Signals |
3-channel, Passive Proximity/Magnetic Pickup |
Speed Range |
0.1 to 30,000 RPM |
Accuracy |
±1 RPM (0 to 10k RPM), ±0.01% (10k+ RPM) |
Threshold Resolution |
0.1 RPM (Programmable) |
Alarm Delays |
0.1 to 60 sec (Adjustable) |
Dynamic Response |
<10 ms (Speed change detection) |
Sensor Gap |
0.25 to 2.5 mm (Recommended) |
Outputs |
4-20 mA (Speed), TTL Alarm (3 per channel) |
Power Supply |
18-30 V DC, 4.5W max |
Operating Temp |
-40°C to +85°C |
Beneficiary's Bank: CITIBANK N.A.
Beneficiary address:Champion Tower,Three Garden Road,Central,Hong Kong
Beneficiary: Vogi International Trading Co., Limited
Account No.: 395714900
Bank Code: 006 Branch Code: 391
Swift Code:CITIHKHX (CITIHKHXXXX * If 11 characters are required)
Payment Term:T/T
Bently Nevada 128240-01 Key Features
Triple-redundant architecture: The 128240-01 utilizes two-out-of-three voting logic, maintaining overspeed protection even in the event of a single channel failure, with an MTBF exceeding 250,000 hours.
Transient capture capability: 10ms-level response speed accurately captures turbine load rejection events, making the Bently Nevada 128240-01 a recommended solution for API 670 standards.
Backlash adaptive technology: Automatically compensates for signal fluctuations caused by gear eccentricity and wear, ensuring measurement stability of the 128240-01 even under degraded lubrication conditions.
Phase-locked filtering: Suppresses harmonic interference from variable frequency drives, maintaining ±0.05% speed accuracy in VFD-powered equipment.
Application examples of foreign nuclear power plants
Nordic geothermal power plant: 12 ORC turbine units utilize 36 128240-01 modules. Using a two-out-of-three logic, the module successfully intercepted two overspeed events in 2023 (triggering time <8ms).
Kuwait seawater booster pump station: In sandy water environments, the 128240-01's backlash compensation technology reduces the speed false alarm rate to 0.001 per year.