Bently Nevada 3300/61 XY Dual Vector Monitor – Vogi international

Vogi international

Bently Nevada 3300/61 XY Dual Vector Monitor

Brand Bently Nevada
Module Number 3300/61
Order Number 3300/61
Unit Price $500
Country Of Origin USA
Weight 0.5kg
Certificate C/O from the Chamber of Commerce
C/Q from the Manufacturer
Warranty 12 Months
Inventory Qty 1

Bently Nevada 3300/61 is a temperature monitoring module, dedicated to real-time temperature monitoring of key parts such as bearings, lubricants, and stator windings of industrial rotating machinery. It continuously collects multi-channel thermocouple or RTD signals to prevent lubrication failure, material deformation, and unplanned downtime caused by equipment overheating.

Bently Nevada 3300/61 Key parameters

Parameter

Specification

Conditions

Input Type

RTD (Pt100) / Thermocouple (J, K, T, E)

Dual-channel redundancy support

Measurement Range

-40°C to +200°C (RTD) / 0°C to 1000°C (TC)

Accuracy: ±1°C (RTD), ±1.5°C (TC)

Alarm Relays

2 per channel (Alert/Danger)

Form A (SPST), 250 Vac/Vdc, 2 A resistive

Power Supply

-24 Vdc ±10%

Via 3300 rack backplane

Response Time

< 500 ms

From sensor input to relay activation

Isolation Voltage

1500 Vrms

Input-to-output, channel-to-channel

Compliance

API 670 (4th Ed.)

Machinery protection standards

Field Wiring

Shielded twisted pair, max 305 m

18–24 AWG, dual-screw terminals

Beneficiary's Bank: CITIBANK N.A.
Beneficiary address:Champion Tower,Three Garden Road,Central,Hong Kong
Beneficiary: Vogi International Trading Co., Limited
Account No.: 395714900
Bank Code: 006 Branch Code: 391
Swift Code:CITIHKHX (CITIHKHXXXX * If 11 characters are required)
Payment Term:T/T

Comparison with similar models and alternatives

Model

Advantages

Disadvantages

Bently Nevada 3300/61

Dual-channel redundancy; Supports multiple temperature sensor types

Limited to temperature monitoring only; No vibration/displacement functionality

3300/16 (Vibration Monitor)

Supports combined vibration/displacement parameters

No dedicated temperature channels; Requires external signal conditioner

Alternative: 3500/61

Integrated System 1® diagnostics; 50% higher channel density

Requires 3500 rack replacement; High upgrade cost

Alternative: 3701 ADAPT

Distributed architecture; Supports wireless transmission

Max 4 temperature channels; Limited redundancy

Upgrade suggestion:

The old 3300 system has been discontinued. Bently Nevada 3300/61 users can migrate to 3500/61: it supports the same sensors and adds self-diagnosis functions (such as open circuit/short circuit real-time alarm), but the rack and backplane need to be replaced.