Honeywell 51305072-300 REV I/O Module
Brand | Honeywell |
Module Number | 51305072-300 |
Unit Price | $500 |
Country Of Origin | USA |
Weight | 0.86kg |
Certificate |
C/O from the Chamber of Commerce C/Q from the Manufacturer |
Warranty | 12 Months |
Inventory Qty | 3 |
Honeywell 51305072-300 is designed for high-precision gas micro-pressure monitoring. Core applications include dynamic airflow control in medical ventilators, positive pressure protection in sterile production lines in pharmaceutical factories, and safety control of laboratory fume hoods.
Honeywell 51305072-300 Key parameters
Parameter |
Specification |
Pressure Range |
0 to 300 |
Supply Voltage |
8 - 30 (DC Excitation) |
Full Scale Output |
100 ± 20 |
Nonlinearity |
±0.15% FSO |
Operating Temperature |
-40 to +125 |
Zero Balance |
±1% FSO |
Response Time |
<0.5 |
Safe Overpressure |
10x Rated Pressure |
Bridge Resistance |
5000 ± 500 |
Media Compatibility |
Dry gases, air |
Beneficiary's Bank: CITIBANK N.A.
Beneficiary address:Champion Tower,Three Garden Road,Central,Hong Kong
Beneficiary: Vogi International Trading Co., Limited
Account No.: 395714900
Bank Code: 006 Branch Code: 391
Swift Code:CITIHKHX (CITIHKHXXXX * If 11 characters are required)
Payment Term:T/T
Honeywell 51305072-300 Key Features
Wide Temperature Range and Extreme Tolerance: The Honeywell 51305072-300 maintains signal stability across the entire -40°C to 125°C temperature range, with measured drift of <0.03% on a desert drilling rig.
Millisecond Response: 0.5ms motion capture capability makes the 51305072-300 the sensor of choice for emergency ventilator equipment.
10x Overpressure Protection: The stainless steel diaphragm structure withstands 3000Pa shock pressure, preventing damage from industrial misoperation.
Millivolt Signal Accuracy: 100mV/V output with a resolution of 0.01Pa, meeting ISO 14644 Class 5 cleanroom standards.
Application examples of foreign nuclear power plants
North American COVID-19 emergency response project: By 2023, Medtronic's ventilator production lines will integrate over 35,000 51305072-300 sensors, ensuring a tidal volume control error of ≤1.5ml.
Swiss pharmaceutical sterile workshop: Roche's Basel site deployed 51305072-300 sensors in 216 isolators, achieving EU GMP Annex 1 certification with zero failures for three consecutive years.
Australian mine safety: Rio Tinto Group's ventilation system uses 1,200 51305072-300 sensors to monitor toxic gas accumulation in real time, with a response delay of <0.3 seconds.

https://cms-site.oss-accelerate.aliyuncs.com/vogi/2025/09/20250901181513809.jpg?x-oss-process=image/format,webp/quality,q_100