Honeywell 51305508-200 REV E XL CNE2
Brand | Honeywell |
Module Number | 51305508-200 |
Unit Price | $500 |
Country Of Origin | USA |
Weight | 0.86kg |
Certificate |
C/O from the Chamber of Commerce C/Q from the Manufacturer |
Warranty | 12 Months |
Inventory Qty | 2 |
Honeywell 51305508-200 is a high-precision, micro-differential pressure sensor designed for low-pressure monitoring in industrial automation and environmental control systems.
Honeywell 51305508-200 Key parameters
Parameter |
Specification |
Pressure Range |
0 to 200 |
Supply Voltage |
5.0 ± 0.25 |
Output Signal |
0.5 to 4.5 (ratiometric) |
Accuracy (25°C) |
±0.25% FSS |
Non-Linearity |
±0.1% FSS |
Operating Temperature |
-20 to +85 |
Storage Temperature |
-40 to +125 |
Response Time |
≤1 |
Long-Term Stability |
±0.25% FSS/year |
Media Compatibility |
Non-corrosive gases |
Port Type |
Dual barbed (Ø3.2 mm) |
Beneficiary's Bank: CITIBANK N.A.
Beneficiary address:Champion Tower,Three Garden Road,Central,Hong Kong
Beneficiary: Vogi International Trading Co., Limited
Account No.: 395714900
Bank Code: 006 Branch Code: 391
Swift Code:CITIHKHX (CITIHKHXXXX * If 11 characters are required)
Payment Term:T/T
Honeywell 51305508-200 Key Features
Precision Temperature Compensation: A built-in full-temperature compensation algorithm ensures the Honeywell 51305508-200 maintains ±0.25% accuracy over the entire -20°C to 85°C temperature range.
Ultra-Low Power Design: Operating current is only 6mA, making it suitable for battery-powered devices and highlighting the 51305508-200's energy efficiency advantage.
Vibration-Resistant Package: The rugged polysulfone housing is IP54 certified, ensuring sensor reliability in high-vibration HVAC environments.
Optimized Linear Output: A 0.5-4.5V ratiometric output signal reduces circuit design complexity.
Application examples of foreign nuclear power plants
European hospital cleanroom systems: Over 12,000 51305508-200 sensors are deployed at the Fresenius Medical Center in Germany, continuously monitoring the positive pressure environment in operating rooms. The failure rate is expected to be less than 0.02% in 2022.
US semiconductor factories: Intel's Arizona wafer fab integrates over 4,600 51305508-200 sensors into its HVAC system, maintaining a Class 1 cleanroom pressure differential accuracy of ±5 Pa.
Data center cooling systems: Google's Netherlands data center uses the 51305508-200 to optimize cold aisle containment, saving 2.3 million kWh annually.

https://cms-site.oss-accelerate.aliyuncs.com/vogi/2025/09/20250901181513809.jpg?x-oss-process=image/format,webp/quality,q_100