TQ912 111-912-000-011 Signal Conditioner

Module Number TQ912
Order Number 111-912-000-011 A1-B6-E5000-F0-G0-H05
Unit Price $1500
Country Of Origin Switzerland
Weight 0.22KG
Certificate C/O from the Chamber of Commerce
C/Q from the Manufacturer
Warranty 12 Months
Inventory Qty 4

The TQ912 111-912-000-011 is a signal conditioner for eddy current sensors designed specifically for industrial rotating machinery, used for non-contact monitoring of mechanical vibration, displacement, and shaft position.

TQ912 111-912-000-011 Key parameters

Parameter

Specification

Matching Transducer

Vibro-Meter TQ 400 Series (e.g., TQ412/TQ432)

Frequency Response

DC to 20 kHz (-3 dB)

Output Modes

Voltage (3-wire) / Current (2-wire)

Voltage Output Range

-1.6 V (min. gap) to -17.6 V (max. gap)

Current Output Range

15 mA (min. gap) to 20 mA (max. gap)

Dynamic Range

16 V (Voltage); 5 mA (Current)

Output Impedance

500 Ω (Voltage)

Short-Circuit Current

45 mA (Voltage mode)

Power Supply

-20 V to -32 V DC

Operating Current

13 ±1 mA (25 mA max.)

Operating Temperature

-30°C to +70°C

Protection Class

IP40

Certifications

CENELEC EEx ib IIC T6, API 670 compliant

Beneficiary's Bank: CITIBANK N.A.
Beneficiary address:Champion Tower,Three Garden Road,Central,Hong Kong
Beneficiary: Vogi International Trading Co., Limited
Account No.: 395714900
Bank Code: 006 Branch Code: 391
Swift Code:CITIHKHX (CITIHKHXXXX * If 11 characters are required)
Payment Term:T/T

TQ912 111-912-000-011 Compatible products

Core Sensor: Must be used with a TQ 400 series eddy current probe (e.g., TQ412 111-412-000-013), with a measurement range of 5mm and cable lengths of 5m or 10m.

Safety Isolation Module: Requires use with a GSI 123 galvanic isolation unit (e.g., GSI127 244-127-000-017) to provide galvanic isolation and prevent ground loop interference.

System Integration Components:

Rack Power Supply: VM600 series rack power supply module (-24VDC output).

Processor Unit: Such as the VIPrime system monitoring card.

Comparison with similar models and alternatives

Model

TQ912 111-912-000-011

IQS452 204-452-000-031

Bently Nevada 3300 XL

Range Compatibility

TQ4x3 probes (5mm range)

TQ4x2 probes (2mm range)

Universal probes

Output Type

Dual-mode Voltage/Current

Voltage only

Dual-mode Current/Modbus

Explosion-proof Cert.

CENELEC EEx ib IIC T6

Same as left

ATEX & IECEx dual-certified

Channel Density

Single channel

Same as left

Expandable to 8 channels

Replaceability

Yes (Standard version)

Yes (Different range)

Yes (Requires system modification)

Alternative suggestions

Direct replacement: IPC704 multi-channel conditioners (such as the 244-704-000-042), which support 4-channel integration and are 40% more expensive but save cabinet space.

Functional replacement: Monitran MTN/1185 series vibration transmitters, but these only support acceleration signals and are not compatible with eddy current probes.

图片2