Bently Nevada 3300/40 eccentricity monitor is specially used for measuring shaft eccentricity of rotating machinery. It can prevent friction failure caused by thermal stress or gravity by real-time monitoring of shaft bending deformation under cold/hot state.
Bently Nevada 3300/40 Key parameters
Parameter |
Specification |
Conditions |
Input Voltage |
-17.5 Vdc to -26 Vdc (without barriers) |
-23 Vdc to -26 Vdc (with barriers) |
Power Consumption |
≤ 12 mA |
-24 Vdc supply |
Output Resistance |
50 Ω |
10 kΩ load |
Linear Range |
1.5 mm (60 mils) |
From 0.25 mm to 1.75 mm gap |
Scale Factor |
7.87 V/mm (200 mV/mil) |
AISI 4140 steel target, 1.0 mm gap |
Field Wiring |
0.2–1.5 mm² (16–24 AWG) |
Max length: 305 m (1,000 ft) |
Operating Temp. |
0°C to +45°C (+32°F to +113°F) |
Max altitude: 2,000 m |
Probe Compatibility |
3300 RAM/NSv Proximity Probe & Extension Cable |
Gold-plated ClickLoc connectors |
Signal Attenuation |
< 2 mV/V (supply sensitivity) |
Per volt change in input voltage |
Beneficiary's Bank: CITIBANK N.A.
Beneficiary address:Champion Tower,Three Garden Road,Central,Hong Kong
Beneficiary: Vogi International Trading Co., Limited
Account No.: 395714900
Bank Code: 006 Branch Code: 391
Swift Code:CITIHKHX (CITIHKHXXXX * If 11 characters are required)
Payment Term:T/T
Comparison with similar models and alternatives
Model |
Advantages |
Disadvantages |
Bently Nevada 3300/40 |
Dedicated eccentricity monitoring; High accuracy for cold/hot state deformation |
Limited to eccentricity function; Low expandability |
3300/16 (Vibration Monitor) |
Multi-parameter support (vibration/displacement) |
No dedicated eccentricity algorithm |
Alternative: 3500 Encore |
Doubled channel density; Integrated local display; Legacy system upgrade support |
Replicates 3300 functionality 1:1; No new monitoring types |
Alternative: 3701 ADAPT |
Distributed architecture; Enhanced processor; Compact size |
Only 12 vib + 2 tach channels; Limited compatibility |
Upgrade suggestion: